HTNXT
menú
Vertical Air Compressor Receiver Tank 0.3–5.0 m³ for 0.8–1.3 MPa Systems
Vertical Air Compressor Receiver Tank 0.3–5.0 m³ for 0.8–1.3 MPa Systems

Vertical Air Compressor Receiver Tank 0.3–5.0 m³ for 0.8–1.3 MPa Systems

en stock:
SKU: 7499395618
modelo: SLT0.3/0.8、SLT0.3/1.0、SLT0.3/1.3、SLT0.6/0.8、SLT0.6/1.0、SLT0.6/1.3、SLT1.0/0.8、SLT1.0/1.0、SLT1.0/1.3、SLT2.0/0.8、SLT2.0/1.0、SLT2.0/1.3、SLT3.0/0.8、SLT3.0/1.0、SLT3.0/1.3、SLT5.0/0.8、SLT5.0/1.0、SLT5.0/1.3

{{ variable.name }}

{{ value.name }}

Sollant Air Receiver Tank · SLT Series

Vertical Air Compressor Receiver Tank 0.3–5.0 m³ for 0.8–1.3 MPa Systems

A vertical receiver tank holds compressed air between the compressor and the production line, absorbing pressure pulsation and covering sudden peaks in air demand. The SLT series covers 0.3–5.0 m³ at 0.8, 1.0 or 1.3 MPa, with a carbon steel shell in Q345R or Q245R and flanged connections from DN25 to DN100.

0.3–5.0 m³ volume0.8 / 1.0 / 1.3 MPaQ345R / Q245R shellDN25–DN100 flanged ports
Vertical air compressor receiver tank SLT series with flanged inlet and outlet connections
Vertical air compressor receiver tank, SLT series, fitted with flanged inlet and outlet ports.

Product Summary

The SLT vertical air receiver tank buffers compressed air between the air compressor and the point of use. It absorbs pressure pulsation in the pipeline, stores air for sudden increases in consumption, and lets liquid water drop out before the air travels downstream. Volume runs from 0.3 to 5.0 m³, working pressure is 0.8, 1.0 or 1.3 MPa, and both the inlet and outlet are flanged in DN25 to DN100.

Key Features

  • 0.3–5.0 m³ across 18 model codes — size the receiver to your compressor output instead of oversizing the whole system.
  • Three pressure classes 0.8 / 1.0 / 1.3 MPa — match the tank rating to your actual discharge pressure.
  • Flanged inlet and outlet, DN25 to DN100 — bolts straight onto standard compressed air piping; inlet height 636–936 mm, outlet height 1166–2236 mm.
  • Q345R or Q245R carbon steel shell — pressure-retaining steel grades for receiver duty, with unit weight from 75 to 1120 kg.
  • Spray-molded coating baked at 250 °C — a corrosion-resistant finish built for workshop conditions.
  • Schneider Electric / ABB electrical components — silver contacts rated for more than 3 million operations on the tank's electrical parts.

Technical Specifications

ParameterValue
Volume0.3–5.0 m³
Working pressure0.8–1.3 MPa
Inlet connection sizeDN25 / DN40 / DN50 / DN80 / DN100 mm
Inlet connection height636–936 mm
Outlet connection sizeDN25 / DN40 / DN50 / DN80 / DN100 mm
Outlet connection height1166–2236 mm
Weight75–1120 kg
Shell materialCarbon steel, Q345R or Q245R
ConfigurationVertical receiver

Models and Options

Model codes pair volume with working pressure, for example SLT0.3/0.8 is 0.3 m³ at 0.8 MPa. Six volumes and three pressure classes give 18 codes in the SLT range.

Model codeVolumeWorking pressure
SLT0.3/0.80.3 m³0.8 MPa
SLT0.6/1.00.6 m³1.0 MPa
SLT1.0/1.31.0 m³1.3 MPa
SLT2.0/1.02.0 m³1.0 MPa
SLT3.0/0.83.0 m³0.8 MPa
SLT5.0/1.35.0 m³1.3 MPa

Materials and Structure

The pressure-retaining shell is carbon steel, with Q345R or Q245R specified for the tank body. The external cover uses high-quality cold-rolled steel plate, finished by spray molding and high-temperature baking at 250 °C, which gives the receiver a corrosion-resistant surface that holds up in daily workshop use. Electrical components come from Schneider Electric and ABB, using silver contacts with a service life above 3 million operations so the electrical side of the tank keeps switching reliably over a long period.

Applications

  • Automotive industry — assembly lines and pneumatic tools fed through a receiver that keeps line pressure steady.
  • Machinery manufacturing — continuous workshop operation where the tank sits between the compressor and a refrigerated dryer with precision filters.
  • Food and beverage, electronics — air storage ahead of the point of use where moisture carry-over must be controlled.
  • Chemicals and metallurgy — receiver duty in plants with fluctuating air demand.

Customization

Volume, working pressure, inlet and outlet size and vertical configuration are selected per order, and Sollant supports OEM/ODM customization. Engineering support is available to match the receiver size to your compressor output and demand peaks.

FAQ

What does a vertical receiver tank do in a compressed air system?

It stores air to meet sudden increases in gas consumption, eliminates pulsation in the pipeline, cools the air initially so some liquid water drops out, and supports automatic shutdown of the air compressor.

Which volumes and pressures can I order?

0.3, 0.6, 1.0, 2.0, 3.0 and 5.0 m³ at 0.8, 1.0 or 1.3 MPa — 18 model codes in total.

What connection sizes are available?

Both inlet and outlet are offered in DN25, DN40, DN50, DN80 and DN100 mm.

What steel is the shell made from?

Carbon steel, with Q345R or Q245R used for the pressure-retaining parts.

Can the receiver be supplied together with a dryer and filters?

Yes. Receivers are supplied as part of integrated compressed air systems with refrigerated dryers and precision filters, so the piping network holds stable pressure and downstream equipment receives dry, clean air.

Do you support OEM/ODM orders?

Yes, OEM/ODM customization is supported across the compressed air product range.

What certifications does the manufacturer hold?

ISO 14001 environmental management system certification, certificate number 05126E00664R053, issued by NOA with the scope of air compressor design, production and sales; production follows the ISO 9001 quality management system.

Inquiry Information

Email: info@sollant.com

Tel / WhatsApp: +86 155-8905-3798

Address: No.215, Songri Center, Beihongqiao, Jiading District, Shanghai, China

Send your required volume, working pressure, connection size and site layout, and the engineering team will confirm the matching SLT model. 24/7 engineering after-sales support and original spare parts are available.

Image Filename and Alt Suggestions

  • vertical-air-compressor-receiver-tank-slt-dn-flanged-ports.jpg — Alt: "Vertical air compressor receiver tank SLT series with flanged inlet and outlet"
  • vertical-air-compressor-receiver-tank-slt-250c-coating.jpg — Alt: "Spray-molded coating on the SLT vertical air receiver tank shell"

SEO Title: Vertical Air Receiver Tank SLT Series 0.3-5.0 m³ 1.3 MPa Carbon Steel

Meta Description: Vertical air compressor receiver tank, 0.3–5.0 m³ at 0.8–1.3 MPa. Q345R/Q245R carbon steel shell, DN25–DN100 flanged ports. SLT series, request a quote.

URL Slug: /vertical-air-compressor-receiver-tank-slt/