Skid-Mounted Modular Oxygen Generator with Siemens PLC Control

en stock:
SKU: 6246158641
modelo: SLTZO-5N、SLTZO-8N、SLTZO-10N、SLTZO-12N、SLTZO-15N、SLTZO-20N、SLTZO-25N、SLTZO-30N、SLTZO-35N、SLTZO-40N、SLTZO-50N、SLTZO-60N、SLTZO-80N、SLTZO-100N、SLTZO-120N、SLTZO-150N、SLTZO-180N、SLTZO-200N、SLTZO-220N、SLTZO-250N、SLTZO-300N

{{ variable.name }}

{{ value.name }}
SLTZO Modular Series

Skid-Mounted Modular Oxygen Generator with Siemens PLC Control

A factory-assembled modular oxygen generator for on-site gas production from 5 to 300 Nm³/h, built on a skid for short installation work and a small footprint.

Modular skid-mounted oxygen generator with integrated control panel

Product Summary

The SLTZO modular oxygen generator packages the adsorption towers, air treatment components and Siemens PLC control on a single skid. Compressed air at 0.4-0.6 MPa enters the unit and leaves as oxygen at 0.3-0.5 MPa, with flow options from 5 to 300 Nm³/h. Because the module is assembled and tested before shipment, site work is limited to connecting air, power and the oxygen line, and the compact skid footprint suits plants where floor space is tight.

Key Features

Skid-mounted modular build

The integrated skid design supports plug-and-play installation, removes the need for complex site piping and keeps the required floor space to a minimum.

Dense sieve loading

Vacuum-assisted automatic feeding, dense packing and vibration-table settling increase packing weight by more than 10% for the same volume and reduce the friction coefficient inside the bed.

Siemens PLC one-touch start

The controller starts the module with one command and needs no dedicated on-site personnel; remote interfaces for computers or mobile devices allow live status checks.

Settling compensation

A spring-loaded or pneumatic compression mechanism automatically compensates for carbon molecular sieve volume loss caused by settling, preventing loosening and pulverizing.

Continuous duty components

Reliable air treatment components maintain stable operation for 24-hour continuous running, with a design service life of at least 5 years.

Off-spec gas venting

Gas that fails to meet the quality specification can be vented automatically or manually before it reaches the process.

Technical Specifications

ParameterValue
ConfigurationModular skid-mounted PSA unit
Model rangeSLTZO-5N to SLTZO-300N
Oxygen flow rate5-300 Nm³/h
Compressed air demand1-60 Nm³/min
Inlet pressure0.4-0.6 MPa
Oxygen outlet pressure0.3-0.5 MPa
AdsorbentCarbon molecular sieve
Control systemSiemens PLC with remote monitoring interfaces
Operating mode24-hour continuous operation
Design service lifeAt least 5 years
Main materialsAluminum alloy, stainless steel, carbon steel
Environmental certificationISO 14001, certificate scope covers air compressor design, production and sales

Models and Options

Twenty-one model sizes are available, from SLTZO-5N through SLTZO-300N, spanning the 5-300 Nm³/h oxygen flow range. Each model is specified together with the compressed air demand of 1-60 Nm³/min, so the module can be sized against the air compressor already installed on site.

Materials and Structure

Aluminum alloy, stainless steel and carbon steel are used for the module frame and pressure vessels. The adsorbent is loaded by an integrated process and held under compression inside the towers, while the air treatment components upstream protect the carbon molecular sieve from moisture and particulate carry-over.

Applications

  • Laser cutting assist gas, used with the air compressor, filters, dryer and air tank in a skid-mounted on-site gas generation solution
  • Electronics manufacturing
  • Metal processing
  • Air separation industry projects requiring distributed oxygen supply

Customization

Carbon molecular sieve is sourced through partnerships with domestic and international sieve manufacturers, so the module can be configured for the most energy-efficient operation under the customer actual working conditions. Remote connectivity interfaces are included, and OEM/ODM customization is supported.

FAQ

What does modular mean for installation?

The towers, air treatment components and PLC come assembled on one skid, which supports plug-and-play installation, avoids complex site piping and keeps the footprint small.

Which flow rates can the module cover?

From 5 to 300 Nm³/h across the SLTZO-5N to SLTZO-300N model range.

What air supply must I provide?

Compressed air at 1-60 Nm³/min and an inlet pressure of 0.4-0.6 MPa; oxygen is delivered at 0.3-0.5 MPa.

Can the module run without an operator?

Yes. Siemens PLC control allows one-touch startup, and remote interfaces for computers or mobile devices let staff monitor status without standing at the unit.

How long does the molecular sieve last?

The system is designed for 24-hour continuous operation with a service life of at least 5 years; even airflow distribution, dense loading and the compression mechanism all work to protect the sieve.

Can the module be combined with other gas equipment?

Yes. It is specified alongside air compressors, filters, air dryers and air tanks in integrated on-site gas generation solutions for laser cutting.

Is customization possible?

Yes. Sieve selection is matched to site conditions, and OEM/ODM customization is supported.

Size a Modular Oxygen Generator for Your Line

Send your required oxygen flow, available compressed air capacity and installation space, and the team will propose the matching SLTZO module.

info@sollant.com

Tel / WhatsApp: +86 155-8905-3798 | No.215, Songri Center, Beihongqiao, Jiading District, Shanghai, China

Image Filename and Alt Suggestions

modular-oxygen-generator-sltzo-skid-front.png
Alt: Skid-mounted SLTZO modular oxygen generator seen from the front
modular-oxygen-generator-sltzo-control-panel.png
Alt: Siemens PLC control panel on the modular oxygen generator
modular-oxygen-generator-sltzo-installed-line.png
Alt: Modular oxygen generator connected to an on-site gas supply line