HTNXT
menú
PIOON M3 980nm Podiatry Laser with Adjustable Zoom Handpiece
PIOON M3 980nm Podiatry Laser with Adjustable Zoom Handpiece

PIOON M3 980nm Podiatry Laser with Adjustable Zoom Handpiece

en stock:
SKU: 3899431634
modelo: M3 Podiatry

{{ variable.name }}

{{ value.name }}
SEO Title980nm Podiatry Diode Laser with Non-Contact Zoom and Focusing Handpieces
Meta DescriptionPIOON M3 980nm 15W podiatry laser configured with non-contact surgical zoom and focusing handpieces for nail and superficial vascular treatment procedures.
URL Slugpioon-m3-podiatry-zoom-handpiece-laser

PIOON M3 980nm Podiatry Laser with Adjustable Zoom Handpiece

PIOON M3 podiatry laser configured for non-contact handpiece delivery

M3 podiatry laser with non-contact zoom and focusing handpiece configuration.

Product Summary

This M3 configuration pairs the 980nm, 15W PIOON diode laser platform with a non-contact delivery setup built around the surgical zoom handpiece and the focusing handpiece. Instead of a single fixed spot, the zoom handpiece provides an adjustable treatment spot for nail and superficial vascular work, while the focusing handpiece provides defined spot sizes for targeted procedures. The same console keeps 7-inch HD touchscreen control through PIOON Smart OS, CW, pulsed and single pulse modes, and an SMA905 port for 400µm or 600µm medical fibers.

Key Features

Surgical Zoom Handpiece

Adjustable treatment spot for non-contact delivery, suited to nail and superficial vascular procedures where the working spot must change between steps.

Focusing Handpiece

Defined spot sizes for targeted non-contact laser procedures, giving a repeatable delivery geometry for clinics standardising protocols.

Nail Plate Energy Delivery

Laser energy can be delivered through the nail plate for selected adjunctive nail fungus treatment protocols.

980nm 15W Output, Three Modes

Continuous wave, pulsed and single pulse delivery at up to 15W, with adjustable power for different procedures.

7-Inch HD Touchscreen with Smart OS

Clinical treatment presets and direct parameter adjustment on a vivid touchscreen interface.

SMA905 Fiber Port

Accepts 400µm and 600µm medical optical fibers, so the console can serve contact and non-contact work.

Technical Specifications

Laser typeMedical diode laser
Wavelength980 nm
Maximum output power15 W
Delivery configurationNon-contact surgical zoom handpiece and focusing handpiece, fixed focus handpiece also available
Operating modesContinuous (CW) / Pulse / Single pulse
Aiming beam650 nm, below 5 mW, adjustable intensity
Display7-inch HD vivid touchscreen
Operating systemPIOON Smart OS
Fiber connectionSMA905
Fiber compatibility400 µm / 600 µm
HousingABS + PC polymer composite
Dimensions (L x W x H)210 x 165 x 160 mm
Power supply18 V DC, 5 A
Foot controlOptional wired or Bluetooth foot pedal

Models and Options

  • Zoom configuration for clinics that work mainly without tissue contact on nails and superficial vessels.
  • Focusing configuration for defined spot sizes in targeted non-contact procedures.
  • Fixed focus handpiece can be added for precise contact delivery in selected soft tissue and superficial vascular procedures.
  • Fiber options of 400µm or 600µm on the standard SMA905 connector.
  • Foot control as wired or Bluetooth pedal, plus protective eyewear, medical-grade power adapters and fiber holders.

Materials and Structure

The console uses an ABS + PC polymer-composite housing measuring 210 x 165 x 160 mm. The proprietary laser stabilization system manages heat generation inside the laser module to support stable operation during extended use with reduced operating noise. The SMA905 connector at the fiber port keeps handpiece and fiber changes simple in a treatment room, and the 7-inch HD touchscreen carries all parameter settings.

Applications

Nail Fungus Protocols

Energy delivered through the nail plate for selected adjunctive onychomycosis treatment.

Nail Matrix Procedures

Supports laser-assisted matricectomy and targeted nail matrix work for ingrown toenails.

Spider Veins and Telangiectasia

Non-contact treatment options for selected superficial vascular lesions on the foot.

Foot Inflammation Support

Supportive laser therapy options for selected conditions involving pain and inflammation.

Clinical applications and treatment outcomes depend on professional assessment, device configuration and locally approved indications.

Customization

PIOON provides OEM services, product training, technical assistance and after-sales support for international distributors. Handpiece combination, fiber size and foot control type are specified at ordering so the delivered unit matches the non-contact workflow a clinic or distributor intends to run.

Certification and Quality Compliance

  • ISO 13485:2016 certificate covering design and development, production and distribution of therapy laser and medical diode laser, audited by TUV SUD Product Service GmbH.
  • CE certificate under MDD 93/42/EEC, Annex II excluding (4), for the quality assurance system of Therapy Laser / Medical Diode Laser.
  • Certificate of conformity for electromagnetic compatibility (EMC) for the EU / EEA market.

Case Study

Handpiece and accessory demonstrations for podiatry professionals, global, at least 2 years. PIOON ran product demonstrations and technical exchanges with podiatry clinics, foot and ankle specialists, hospital podiatry departments, foot care centers and medical equipment distributors. The programme focused on device and accessory demonstrations, including compatible treatment handpieces, and on professional knowledge sharing within the approved intended use.

FAQ

What is the difference between the zoom, focusing and fixed focus handpieces?

The surgical zoom handpiece gives an adjustable treatment spot for non-contact work, the focusing handpiece gives defined spot sizes for targeted non-contact procedures, and the fixed focus handpiece is used for precise delivery in selected soft tissue and superficial vascular procedures.

Can nail fungus work be done without tissue contact?

Yes. Energy can be delivered through the nail plate for selected adjunctive onychomycosis protocols using the non-contact handpieces in this configuration.

Are numeric spot sizes published for the handpieces?

The zoom handpiece is described as adjustable and the focusing handpiece as providing defined spot sizes. Request the handpiece specification sheet from PIOON for the exact values to plan protocols.

Which fibers can be connected?

The SMA905 port accepts 400µm and 600µm medical optical fibers, covering both finer and larger fiber delivery needs.

Which operating modes are available on this configuration?

Continuous wave, pulsed and single pulse modes remain available, with adjustable power up to 15W at 980nm.

Is the aiming beam adjustable for non-contact work?

The 650nm aiming beam runs below 5mW with adjustable intensity, so the target can be marked at different working distances.

What documentation is available for EU distributors?

PIOON holds an ISO 13485:2016 certificate, a CE certificate under MDD 93/42/EEC Annex II excluding (4), and an EMC certificate of conformity. Verify the registration status of the exact configuration for your market before import.

What are the MOQ, price and delivery terms for this configuration?

They depend on the handpiece and fiber combination selected and on the destination market, and are confirmed in the written quotation after your requirements are reviewed.

Image Filename and Alt Suggestions

  • pioon-m3-podiatry-zoom-handpiece-console.png - M3 console set for non-contact zoom handpiece delivery
  • pioon-m3-podiatry-non-contact-handpiece.png - Non-contact handpiece positioned above a foot for treatment
  • pioon-m3-podiatry-focusing-handpiece-detail.png - Focusing handpiece detail showing defined spot exit
  • pioon-m3-podiatry-fiber-and-pedal.png - Fiber routed from the SMA905 port with foot pedal on clinic floor

Inquiry Information

Request the Non-Contact Handpiece Configuration

Wuhan Pioon Technology Co., Ltd. - 12th Floor, Building 1, Innovative Unit, R and D Center Project, Marine World Shipbuilding Park, No. 16, Fozuling 3rd Road, East Lake High-tech Development Zone, 430205, Wuhan, Hubei, China.

Email: sales@pioon.com | Tel: +86 27 87001110 | WhatsApp: +86 18971249550

Tell us which handpieces and fiber sizes your protocols require so the quotation and documentation package are prepared for your market.

PIOON M3 podiatry laser with handpiece for non-contact treatment
Non-contact handpiece delivery on the M3 podiatry platform
M3 diode laser console with fiber connection in a clinic
SMA905 fiber connection for 400µm and 600µm fibers