High-Power CDU XK-BGCDU 240 to 2,500 kW for AI Data Centers

en stock:
SKU: 835469836X
modelo: DWW30-20C / DWW50-25C; XK-BGCDU-240 / 600 / 1200 / 2500; select each model separately

{{ variable.name }}

{{ value.name }}

High-Power Secondary Loop

High-Power CDU XK-BGCDU 240 to 2,500 kW for AI Data Centers

The XK-BGCDU high-power CDU series provides 240, 600, 1,200 and 2,500 kW capacity options for AI data centers, HPC and integrated liquid-cooling infrastructure. It connects primary cooling to the secondary loop through heat exchange and circulation control.

240 / 600 / 1,200 / 2,500 kWHigh-power seriesAI data center cooling
High-power CDU XK-BGCDU series unit for AI data center cooling
High-power CDU for large AI and HPC secondary-loop cooling.
Installation options across the CDU range include rack-mounted, sidecar and in-row; the final layout for XK-BGCDU models is confirmed per project. Flow rate, differential pressure and supply/return temperature are model-specific.

Product Summary

Four capacity steps for large liquid-cooling loads

The XK-BGCDU series connects primary cooling infrastructure to the secondary loop through heat exchange and circulation control. It is intended for AI data centers, high-performance computing and integrated liquid-cooling infrastructure. Intelligent controls support operating-status monitoring, and the unit integrates with cold plates, piping and monitoring systems. Pump redundancy is project-specific. Flow rate, differential pressure and supply/return temperature are model-specific and confirmed for the selected model and site conditions.

Key Features

Facts tied to the XK-BGCDU series

  • Four high-power steps: 240 kW, 600 kW, 1,200 kW and 2,500 kW models cover different AI and HPC block loads.
  • Secondary-loop heat exchange: Connects primary cooling infrastructure to cold-plate loops.
  • Project-specific pump redundancy: Configured to match availability requirements.
  • Intelligent monitoring: Controls support operating-status monitoring and system integration.
  • Stainless steel wetted path: Plate heat exchanger and internal piping are stainless steel on applicable models; confirm grade and wetted materials.
  • Range installation options: Rack-mounted, sidecar and in-row options exist across the CDU range; confirm the selected XK-BGCDU layout.

Technical Specifications

Catalog specifications and model-specific operating conditions

ParameterXK-BGCDU Series
ModelsXK-BGCDU-240 / 600 / 1200 / 2500
Cooling capacity240 / 600 / 1,200 / 2,500 kW
InstallationProject-specific; range options include rack-mounted, sidecar and in-row
Flow rateModel-specific (m³/h)
Differential pressureModel-specific (kPa)
Supply / return temperatureModel-specific (°C)
Coolant compatibilityConfirmed per project
Pump redundancyProject-specific
Heat exchanger / internal pipingStainless steel on applicable models; confirm grade and wetted materials
ControlsIntelligent operating-status monitoring
IntegrationCold plates, piping and monitoring systems
Rating basisCatalog specifications; model-specific operating conditions

Models and Options

Select capacity by AI or HPC block load

ModelCooling capacitySeries
XK-BGCDU-240240 kWXK-BGCDU high-power CDU
XK-BGCDU-600600 kWXK-BGCDU high-power CDU
XK-BGCDU-12001,200 kWXK-BGCDU high-power CDU
XK-BGCDU-25002,500 kWXK-BGCDU high-power CDU

Materials and Structure

Wetted-path confirmation is project-specific

Plate heat exchanger and internal piping are stainless steel on applicable models. Confirm exact grade and wetted materials for the selected model and coolant. The high-power CDU groups heat exchange, circulation and control functions for the project layout. Pump redundancy is project-specific. For site integration, confirm freeze protection, condensation prevention, corrosion protection, noise, electrical supply and local certification requirements.

Applications

Large AI, HPC and integrated liquid-cooling deployments

AI Data Centers

High-power secondary-loop cooling for dense AI halls.

HPC

Cold-plate cooling for high-performance computing clusters.

Direct-to-Chip

Connects primary cooling to direct-to-chip secondary loops.

Integrated Liquid Cooling

Fits integrated liquid-cooling infrastructure and phased builds.

Customization

Project-defined configuration

  • Capacity: Select XK-BGCDU-240, 600, 1200 or 2500.
  • Pump redundancy: Configured per project.
  • Integration: Cold plates, piping and monitoring systems.
  • Coolant: Compatibility confirmed per project with wetted materials checked.
  • Factory integration: Prefabrication, integrated commissioning and factory testing; the technical agreement defines configuration, delivery and certification scope.

FAQ

Procurement and engineering questions

Which models are available and how is capacity selected?

XK-BGCDU-240, 600, 1200 and 2500 cover 240 kW, 600 kW, 1,200 kW and 2,500 kW. Selection depends on IT load, supply and return temperatures, redundancy target and site conditions.

What installation options apply?

The CDU range includes rack-mounted, sidecar and in-row options. The final XK-BGCDU layout is confirmed with engineering for each project.

What flow rate and differential pressure does the CDU provide?

Flow rate and differential pressure are model-specific and confirmed against the selected model, IT load and project operating conditions.

What coolant can be used?

Coolant compatibility is confirmed per project. Wetted materials are checked against the selected model and coolant.

Can pump redundancy be specified?

Yes. Pump redundancy is project-specific and configured to match the availability requirement.

Does the CDU support monitoring?

Intelligent controls support operating-status monitoring and integration with monitoring systems.

What certifications apply?

The manufacturing site holds ISO 9001:2015 and ISO 14001:2015 certificates. The certified scope covers R&D and production of cloud computing liquid cooling equipment and controls. Project-specific certification scope is confirmed separately.

What information is needed for a quote?

Provide IT load, supply and return temperatures, flow and pressure requirements, coolant, redundancy target, installation layout and site conditions.

Inquiry Information

Send project requirements to the Xinke Intelligent Technology team for high-power CDU selection and configuration review.

Email: sales@xinkelcs.com
WhatsApp: +86 18133557330
China hotline: 400-106-2272
Website: www.xinkelcs.com
Address: Guye Economic Development Zone, Tangshan, Hebei, China

Image Filename and Alt Suggestions

Use product, model and angle in filenames

Main image filename: cdu-xk-bgcdu-high-power-unit.png
Alt text: High-power CDU XK-BGCDU series unit for AI data center cooling

Detail image filename: cdu-xk-bgcdu-1200-high-power-connections.png
Alt text: XK-BGCDU-1200 high-power CDU piping connection side

SEO Title: High-Power CDU XK-BGCDU 240 to 2,500 kW for AI Data Centers

Meta Description: XK-BGCDU high-power CDU models at 240, 600, 1,200 and 2,500 kW connect primary cooling to AI data center secondary loops with project pump redundancy.

URL Slug: /products/high-power-cdu-xk-bgcdu-240-2500-kw