menú

Altitude-Compensated Screw Airend for On-Board Oxygen Generation

en stock:
SKU: 3522910478
modelo: GCU33

{{ variable.name }}

{{ value.name }}

Altitude-Compensated Screw Airend for On-Board Oxygen Generation

GCU33 integrated screw airend for plateau locomotive and coach oxygen / nitrogen systems — oil carry-over ≤3 ppm, −40 °C to +50 °C design, operation up to 5,000 m.

Up to 5,000 m−40 °C to +50 °COil Carry-Over ≤3 ppm9-in-1 Integrated

SEO TitleGCU33 Altitude-Compensated Screw Airend for Plateau On-Board Oxygen Generation

Meta DescriptionGCU33 screw airend for plateau oxygen generation: altitude compensation port, −40 °C to +50 °C, oil carry-over ≤3 ppm, 5–12.5 bar, up to 5,000 m operation.

URL Slug/products/gcu33-screw-airend-plateau-oxygen-generation

H1Altitude-Compensated Screw Airend for On-Board Oxygen Generation

Product Summary

Plateau rail service demands compressed air that is clean, dry and consistent, because it feeds the oxygen and nitrogen generators serving passengers and crew. The GCU33 is configured for that duty with an altitude oxygen compensation intake port, a design range of −40 °C to +50 °C and oil carry-over held at or below 3 ppm, delivering 2.3–3.9 m³/min at 7 bar within a 5–12.5 bar range.

The 9-in-1 assembly combines the screw airend, an oil-gas separator tank with built-in coarse separator, three filters and four valves, so the coach or locomotive builder installs one pressure-ready unit of 74 kg in a 477 × 438 × 633 mm envelope excluding the air filter assembly. Noise is rated at or below 75 dB(A), and the unit is specified for continuous duty during plateau operation, matched with an air dryer and precision filter upstream of the generator.

GCU33 altitude-compensated screw airend for on-board oxygen generation, front view
GCU33 integrated screw airend separator tank and filters for clean air supply

Key Features

Altitude Compensation Intake

An altitude oxygen compensation intake port maintains stable pressure and delivery in thin air at altitudes up to 5,000 m.

Oil Carry-Over ≤3 ppm

Coarse separator in the tank plus an oversized external fine separator keep the airstream within the ≤3 ppm design limit required by downstream generators.

Wide Temperature Design

The platform is designed for −40 °C to +50 °C, covering the day and night temperature difference of plateau routes.

One-Piece Installation

Nine integrated functions in a single 74 kg unit reduce connection work inside a locomotive or coach air bay.

Continuous Plateau Duty

Specified for continuous operation with automatic pressure regulation, with a maximum discharge temperature of 105 °C.

Proven Rotor and Seal Package

Forged alloy steel rotors on a German-designed UV patented profile, SKF bearings and triple-sealing shaft technology.

Technical Specifications

ModelGCU33
TypeWide-range integrated screw airend; vehicle / general purpose
Power15–30 kW
Speed3100–6000 rpm
FAD at 7 bar2.3–3.9 m³/min
Working pressure5–12.5 bar (max. 12.5 bar / min. 5 bar)
Max. discharge temperature105 °C
Oil carry-over<2 ppm (design ≤3 ppm)
Noise≤75 dB(A)
Net weight74 kg
Dimensions (L×W×H)477 × 438 × 633 mm, excluding air filter assembly
Plateau configurationAltitude oxygen compensation intake port; −40 °C to +50 °C design; dry, oil-free air at ≤3 ppm
Integrated configuration9-in-1: screw airend + oil-gas separator tank (built-in coarse separator) + 3 filters (external fine oil separator, oil filter, air filter optional) + 4 valves (intake control valve, minimum pressure valve, thermostat valve, safety valve)
MaterialsHigh-grade cast iron housing; forged alloy steel rotors; SKF heavy-duty rolling bearings; triple-sealing shaft seal
ComplianceCE (TUV Rheinland, CE-WSD-GCU-2023-001, valid to 2028-06-14); ISO 9001:2015; IATF 16949:2016

Models and Options

  • Altitude package — oxygen compensation intake port and −40 °C to +50 °C design specification.
  • Filtration train — air filter supplied as part of the package or optional, matched with the vehicle air dryer and precision filter.
  • Architecture — conventional airend or 9-in-1 integrated unit from one source.
  • Housing — high-grade cast iron standard; aluminium-alloy housing under development.
  • Mounting — standardised interface and technical drawings for locomotive and coach air bay integration.

Materials and Structure

Compression takes place between forged alloy steel rotors machined to a German-designed UV patented profile (patent ZL2012 1 0087353.0) in more than 20 precision steps, carried on SKF heavy-duty rolling bearings and sealed by a triple-sealing shaft arrangement. Separation is two-stage: a built-in coarse separator inside the oil-gas tank followed by an oversized external fine oil separator. The high-grade cast iron housing encloses the airend and the factory-fitted valve group, with the minimum pressure valve, thermostat valve, intake control valve and safety valve regulating the air delivered to the downstream dryer and generator.

Applications

Configured for plateau oxygen and nitrogen generation and related rail air supply duties.

  • On-board oxygen and nitrogen generation on plateau locomotives and coaches, fed through an air dryer and precision filter.
  • Locomotive and rail vehicle main air source system.
  • Continuous duty during plateau operation at altitudes up to 5,000 m.
  • Aftermarket replacement and vehicle air system retrofit programmes.

Customization

Altitude compensation, temperature design range, filtration arrangement and mounting interface are agreed per project, with technical drawings issued for the vehicle air bay. Because the airend output feeds a dryer and generator, the specification is normally fixed together with those downstream components so that pressure, flow and oil carry-over match the oxygen or nitrogen plant requirement.

Case Study

Plateau Locomotive / Coach Oxygen Supply Project300 Units

Two-year programme supplying clean, water-free compressed air for on-board oxygen and nitrogen generation. Reported result: normal operation at altitudes up to 5,000 m with stable pressure and delivery. Highlights: altitude oxygen compensation intake port, −40 °C to +50 °C design, oil carry-over ≤3 ppm.

Project ContractorAftermarket and Retrofit

Approx. 300 units shipped cumulatively over 2 years for aftermarket replacement and vehicle air system retrofit. Reported result: CE-compliant supply with purchase cost 25–30% lower than comparable European airends of equivalent performance. Highlights: drop-in replacement dimensions and a 4–5 week lead time versus 8–10 weeks for imports.

FAQ

How is performance maintained in thin plateau air?

An altitude oxygen compensation intake port is specified for the plateau configuration, and the programme referenced operation at altitudes up to 5,000 m with stable pressure and delivery.

Is the air clean enough for an oxygen generator?

The design limit for oil carry-over is 3 ppm, with measured carry-over below 2 ppm, and the unit is matched with an air dryer and precision filter before the generator.

What temperature range is the design specified for?

−40 °C to +50 °C, covering the large day and night temperature difference on plateau routes.

What are the flow, pressure and power figures?

2.3–3.9 m³/min FAD at 7 bar within a 5–12.5 bar working range, at 15–30 kW and 3100–6000 rpm, with maximum discharge temperature of 105 °C.

Can it replace an imported airend directly?

In the referenced programme the unit matched drop-in replacement dimensions, and a standardised mounting interface with technical drawings is provided for integration.

Which certifications support export supply?

CE issued by TUV Rheinland (CE-WSD-GCU-2023-001, valid to 14 June 2028) covering integrated screw airends and vehicle-mounted screw air compressors from 2.2 to 45 kW, plus ISO 9001:2015 and IATF 16949:2016.

Inquiry Information

Wuxi Woyo Superdo Compressor Co., Ltd. (brand WOLXAIR), founded 1996, 20,000 m² facility, 120+ staff, 12,000 units annual output.

Email: service@woyo.cn · Tel: +86 510 8599 6655 · WhatsApp / Mobile: +86 189 1237 9878

Address: No.5 Changkang Road, Mashan, Binhu District, Wuxi, Jiangsu, China · www.woyocomp.com

Please confirm operating altitude, required FAD and pressure, downstream dryer and generator specification, and annual quantity so the plateau configuration can be quoted. MOQ, price and delivery are confirmed per configuration.

Image Filename and Alt Suggestions

  • gcu33-screw-airend-plateau-oxygen-front.png — alt: GCU33 altitude-compensated screw airend for on-board oxygen generation, front view
  • gcu33-screw-airend-plateau-separator-tank.png — alt: GCU33 integrated screw airend separator tank and filters for clean air supply
  • gcu33-screw-airend-plateau-valve-detail.png — alt: GCU33 screw airend minimum pressure and thermostat valve detail
  • gcu33-screw-airend-plateau-mounting-side.png — alt: GCU33 screw airend mounting base for locomotive air bay installation, side view