{{ variable.name }}
A plateau-ready integrated screw airend for on-board oxygen and nitrogen generation, with altitude oxygen compensation intake port, -40 C to +50 C design, and oil carry-over at or below 3 ppm.
The GCU55L plateau configuration supplies clean, water-free compressed air for on-board oxygen and nitrogen generation on locomotives and coaches. It is designed for altitudes up to 5,000 m, with an altitude oxygen compensation intake port and a -40 C to +50 C operating design. The 9-in-1 integrated layout combines the screw airend, oil-gas separator tank, filters, and valves to reduce underframe plumbing. Oil carry-over is controlled at 3 ppm or less for oxygen-generation air preparation. The core air block delivers 6.3-8.1 m3/min FAD at 7 bar and up to 16 bar working pressure.
| Model | GCU55L |
|---|---|
| Power | 30-37 kW |
| Speed | 4100-6000 rpm |
| FAD at 7 bar | 6.3-8.1 m3/min |
| Max. / min. working pressure | 16 / 5 bar |
| Max. discharge temperature | 105 C |
| Oil carry-over | <=3 ppm for plateau oxygen supply configuration |
| Noise | <=75 dB(A) |
| Net weight | 173 kg |
| Dimensions (L x W x H, excl. air filter assembly) | 600 x 650 x 585 mm |
| Plateau configuration | Altitude oxygen compensation intake port; -40 C to +50 C design; operation up to 5,000 m |
The GCU55L plateau configuration is specified around the altitude compensation intake port, low oil carry-over, and wide temperature design. A 9-in-1 integrated architecture is used for compact underframe installation. For 16 bar and higher service, the external fine separator, oil filter, and safety valve must be rated at 20 bar or above. Air filter assembly and port orientation can be reviewed against the vehicle interface.
GCU55L plateau5,000 m-40 C to +50 COil carry-over <=3 ppm
The airend uses a high-grade cast iron housing, forged alloy steel screw rotors with a German-designed UV patented rotor profile, SKF heavy-duty rolling bearings, and triple-sealing technology. The oil separation system combines a built-in coarse separator with an oversized external fine separator. The plateau configuration adds an altitude oxygen compensation intake port and is designed for -40 C to +50 C service, supporting stable pressure and delivery in thin-air conditions.
Plateau locomotive and coach oxygen supply projects, on-board oxygen and nitrogen generation, rail vehicle air systems, and aftermarket replacement or vehicle air system retrofit. The unit is matched with oxygen or nitrogen generators, air dryers, and precision filters. Continuous duty during plateau operation is supported by the integrated oil separation and thermal management layout.
Plateau projects can specify altitude compensation intake port, -40 C to +50 C design, oil carry-over limit, 9-in-1 or conventional architecture, port orientation, and mounting interface. For oxygen-generation duty, the air preparation chain should be confirmed together with the dryer and precision filter. For 16 bar and higher systems, the external fine separator, oil filter, and safety valve must be rated at 20 bar or above.
Plateau locomotive and coach oxygen supply project: 300 units over two years for clean, water-free compressed air used in on-board oxygen and nitrogen generation. The units operated normally at altitudes up to 5,000 m with stable pressure and delivery. The configuration included an altitude oxygen compensation intake port, -40 C to +50 C design, and oil carry-over at or below 3 ppm.
Aftermarket replacement and retrofit: approximately 300 units shipped cumulatively over two years, with CE-compliant supply and purchase cost 25-30% lower than comparable European airends with equivalent performance. Drop-in replacement dimensions and a 4-5 week lead time supported retrofit schedules.
Can the GCU55L operate at 5,000 m altitude?
The plateau configuration is designed for operation up to 5,000 m and includes an altitude oxygen compensation intake port for thin-air conditions.
What oil carry-over is specified for oxygen generation?
The plateau oxygen supply configuration is specified at 3 ppm or less oil carry-over to support clean air preparation.
What is the operating temperature design?
The plateau configuration is designed for -40 C to +50 C to cover large day and night temperature differences.
Is the 9-in-1 layout included?
Yes. The 9-in-1 layout combines the screw airend, oil-gas separator tank, three filters, and four valves for compact underframe installation.
What pressure class is supported?
The GCU55L supports 16/5 bar working pressure. For 16 bar and higher systems, the external fine separator, oil filter, and safety valve must be rated at 20 bar or above.
Please share the operating altitude, required oil carry-over, oxygen or nitrogen generation air preparation chain, temperature range, mounting interface, and pressure class. Drawings and interface details can be reviewed before order confirmation.
Contact: Overseas Sales Team | Email: service@woyo.cn | Tel: +86 510 8599 6655 | WhatsApp: +86 189 1237 9878